JFV1500B Mechanical Damp Foot Valve
1. JFV1500B foot valve maximum pressure: Max.1500bar, maximum flow: Max.80l/min, do not overpressure use!
2. All threaded joints must be coated with stainless steel anti-bite agent during installation. Remember!
3. When removing the overflow cartridge assembly 1, loosen the spool gland with an open wrench and the cartridge assembly 1 will be pulled out with it.
4. When installing insert valve assembly 1, insert the front t-table of the overflow spool into the groove of the spool gland, and apply a small amount of grease on the “O” ring and plastic sealing ring outside the overflow spool to prevent damage to the “O” ring and plastic sealing ring during the installation of the spool.
5. When replacing the combination seal (” O “ring + plastic seal ring) of high-pressure inlet and outlet and water joint 3 (” O” ring + plastic seal ring), please pay attention to the sequence of the two, that is, “O” ring contacts high-pressure water first, and the groove in the plastic seal is connected with “O” ring.
6. In order to extend the service life of overflow cartridge valve, step the pedal firmly when cleaning.